Previously, the NO_RETURN_IN_FUNCTION_WITH_BLOCK_BODY diagnostic was not
reported at all on functions which return Nothing. However, in K1, if
the function returns Nothing but the body is empty or doesn't contain a
Nothing expression, this diagnostic would be reported. The checker in K2
has been updated to report this diagnostic on functions which return
Nothing as well.
^KT-55965 Fixed
When an inline lambda is invoked or passed to another inline function,
make sure non-local returns are allowed by all surrounding declarations.
Otherwise, NON_LOCAL_RETURN_NOT_ALLOWED must be reported.
^KT-59884 Fixed
^KT-55319 Fixed
Currently, PROPERTY_WITH_NO_TYPE_NO_INITIALIZER is reported for local
variables, but not reported for member or top-level properties. Add a
check to the common `checkPropertyInitializer` for when a property
type cannot be determined from the getter.
This also corrects a K1 versus K2 inconsistency, where K2 would allow
blocks from getters to determine property type instead of only allowing
expression bodies.
^KT-59935 Fixed
^KT-60117 Fixed
^KT-60123 Fixed
When the left-hand side of an equality comparison is known to be a
String, and the equality condition resolves to true, then the right-hand
side can be smart-cast to a String as well. This was working for String
expressions on the left-hand side but not for String constants.
^KT-57513 Fixed
Anonymous functions (lambdas) are not allowed as annotation arguments.
However, because it is still possible to parse code written this way, it
must be handled without exception. So ignore these expressions when
processing annotation arguments.
#KT-59565 Fixed
When computing the conversion type for a type operator call, the
argument needs to be fully unwrapped before getting the resolved type.
This avoids the situation when the argument is a when-subject and the
assumed original type is not correct. Before, only smart-casts were
unwrapped, and this change will also unwrap when-subjects (as well as a
few other FirExpressions).
^KT-62114 Fixed
There are conditions where the data-flow analysis for a control-flow
graph node is delayed. Make sure that when completing a graph, all nodes
within the graph have completed their data-flow analysis.
^KT-61794 Fixed
If the modality of a property is not final, the modality of the dispatch
receiver can be used to determine if the property is stable. When
looking up the dispatch receiver symbol, make sure to unwrap the lower
bounds of flexible types.
^KT-61735 Fixed
When checking top-level properties, check with initialization enabled.
This makes sure the same errors are reported for member and top-level
properties.
UncaughtExceptionPath edges are used to influence smart-casting within
catch and finally blocks. Previously these edges were added from every
node which could throw an exception. But only assignment nodes influence
smart-casts by resetting inference back to some less specific type.
Therefore, instead of tracking every possible node which could throw an
exception - even though almost every statement node can - only add edges
from assignment nodes to catch and finally blocks. This fixes many
missing exception cases and also reduces the total number of incoming
edges to catch and finally blocks.
#KT-56872 Fixed
Now that files have a CFG, use it to validate properties are initialized
correctly. Update FirTopLevelPropertiesChecker to collect initialization
info for the property being checked - similar to
FirMemberPropertiesChecker - and validate proper initialization.
#KT-56683 Fixed
#KT-58531 Fixed
In order to properly analyze top-level property initialization, a
control-flow graph must be created for FirFiles. This change adds the
foundation for the file CFG and updates body resolve to create the CFG.
Checking the CFG for proper initialization is separated into a following
change to ease code review.
KT-56683
When checking for class val property reassignment diagnostic, property
initializers should be treated as part of the class initialization.
However, property accessors should not. Previously, only the property
itself was checked for both of these situations and resulted in not
reporting diagnostic within property accessors.
#KT-59744 Fixed
Instead of trying to use node and edge information to determine when an
alternate flow no longer needs to be propagated, ask the CFG builder if
the node is still within the `finally` blocks of the paths being
propagated. This makes the checks simpler and more sound, avoiding leaks
of alternate flows beyond their needed scope.
KT-56888
Added a new FIR based checker for both FINITE_BOUNDS_VIOLATION and
FINITE_BOUNDS_VIOLATION_IN_JAVA errors. Implementation copied from the
existing descriptor based checker with some minor changes.
#KT-59378 Fixed
In preparation for KT-58531, LL FIR resolvers need to support resolving
FirFiles. This change has a very large impact on test data, so it is
being made separately.
Entering a `finally` block can happen from many different places:
through an exception, a jump, or normal exit from the `try` block. When
in the `finally` block, all DFA flows must be merged to have correct
smart casting. However, after the `finally` block, if exiting normally
or because of a jump, the combined flow from within the `finally` block
should not be used, but rather an alternate flow which combines the
correct flows from before the `finally` block.
```
try {
str as String // Potential cast exception
} finally {
str.length // Shouldn`t be resolved
}
str.length // Should be resolved
```
When building DFA flows, track the start of possible alternate flows,
and continue building them until they end. Both of these situations are
now marked on CFGNodes via interfaces.
When building the default DFA flow, and the source node is the end node
of alternate flows, attempt to use the alternate flow with the same edge
label instead of the default flow of the source node.
#KT-56888 Fixed
Preliminary refactor in preparation for the implementation details to
fix KT-56888. This change makes it so alternate data flows can be
created and maintained through CFGNodes. This change was separated and
created first to aid in the code review process.
Jump edge targets are maintained globally within the CFG builder and are
added indiscriminately to `finally` exit nodes. This means that a
`finally` exit node could have a jump edge added which doesn't match how
the `finally` block was entered. Make sure edges are only added to the
exit node if they also exist on the enter node.
#KT-60723 Fixed
Instead of checking for only open declarations, check for overridable
declarations, since private declarations cannot be overridden even if
they are marked as open. While normally these modifiers are exclusive,
a declaration can be made open via a compiler plugin like AllOpen.
#KT-60183 Fixed
#KT-57223 Fixed
The AllOpen plugin can make private members open. But for private
properties, they can be considered stable for smart-casting if they do
not have a custom getter.
#KT-58049 Fixed
Inject delegated constructor and other in-place initializer sub-graphs
after the delegated constructor call node. This ensures property
initialization and use is calculated correctly when there are complex
calculations for the arguments to the delegated constructor.
#KT-59708 Fixed
#KT-59832 Fixed
When one side of an Elvis operator can only be `null`, and the entire
Elvis operator expression cannot be `null`, this implies that the
opposite side of the Elvis operator cannot be `null`. Add such
implications to the Elvis exit node of the DFA. This helps smart-casting
of variables used within long Elvis operator chains.
#KT-49249 Fixed
When a call is resolved to a classifier, only a single error message was
being used for multiple cases. This lead to confusion as the default
message may not be applicable to a given error case. Added additional
errors and messages to distinguish between these error cases.
#KT-57251 Fixed
Previously the argument type was being used for the actual type error
display. However, safe-call arguments are unwrapped which causes
nullable types to be displayed as non-null. Change to use the actual
type provided by the diagnostic instead of extracting the type from
the argument.
#KT-58844 Fixed
To make sure all possible types are resolved and any additional errors
are reported, resolve children of function calls using independent
resolution mode when the callee reference is an error.
#KT-59041 Fixed
Error message was only printing the calling inline function and not the
class member being accessed. Make sure both pieces for diagnostic
information are included in the error message.
#KT-58972 Fixed
Nested classes which are not inner class should not be able to access
type parameters of the outer class. Make sure access is not available
when resolving super types.
#KT-54748 Fixed
Complex enum entries (those with bodies) with missing overrides
are covered by an existing checker that checks all types of classes. But
simple enum entries (those without bodies) were not covered and require
a separate checker for missing overrides.
#KT-58637 Fixed
Attach source information to each argument of the type before expanding
to preserve information during validation. This allows errors to be
reported on the original argument during nested type alias expansion.
^KT-50798 Fixed
^KT-50703 Fixed